▸ Using the SONY ID7000 to maximize your cytometry capabilities and workflow
picture of event poster
February 23, 2024

Using the SONY ID7000 to maximize your cytometry capabilities and workflow

Date and Time: Wednesday, February 21, 2024 11:00 EST
In-person: PMH room 6-604
Description: Can you standardize the ID7000 between users / instruments / longitudinal studies?
Can you utilize your background Autofluorescence as a novel parameter?
Can you avoid creating single stains regardless of a bead or a cell?
What is the benefit of having up to 3x more detectors?

▸ Revealing cellular diversity with the power of spectral cytometry
picture of event poster
February 05, 2024

Revealing cellular diversity with the power of spectral cytometry

Date and Time: Wednesday, February 14, 2024 8:00 PST | 11:00 EST | 16:00 GMT | 17:00 CET
Speaker: Robert Balderas, Vice President Biological Sciences, BD Biosciences
Description: This webcast will review the principles and concepts of spectral flow cytometry, describe current technology innovations, and showcase some of the exciting discoveries made possible by spectral flow cytometry, while also discussing practical tips and best practices for researchers who want to adopt this technology.

2023

▸ BD Horizon NEXT coming to Toronto - September 12, 2023
picture of 46th Annual Course in Cytometry poster
August 10, 2023

BD Horizon NEXT coming to Toronto!
September 12, 2023, 10:00 am - 4:30 pm

This is the latest version of our groundbreaking Horizon Tour that helped flow cytometry users better grasp panel design principles toward cleaner data generation. This time, our event touches on elements of spectral panel design, deep immunophenotyping and sorting, spectral sorting and imaging with the BD FACSDiscover(TM) S8 as well as some data analysis aspects for high parameter assays.

▸ 46th Annual Course in Cytometry - San Diego August 12 - August 18, 2023
picture of 46th Annual Course in Cytometry poster
March 17, 2023

46th Annual Course in Cytometry - San Diego
August 12 - August 18, 2023

San Diego is excited to be the newest location for this long running series of week-long workshops, which provide state-of-the-art information on cutting-edge topics in cytometry.

2022

▸ Deep Science Seminar April 13th, 2022
picture of SBAR flow poster
March 17, 2022

Deep Science Seminar
April 13th, 2022 at 1 p.m. ET

This presentation will highlight how the combined use of high-parameter analytical flow cytometry and advanced single-cell multiomic tools (proteomic and genomic) can help define functional murine NK cell subsets.

▸ Webinar: High-Dimensional High-Throughput Rare Event Immunophenotyping
picture of Holiday announcement
February 17, 2022

Webinar: High-Dimensional High-Throughput Rare Event Immunophenotyping

This webinar will provide insights for researchers who want to learn how spectral technology, such as that on the ID7000, can increase flexibility when using greater than 20 markers in multicolor flow cytometry experiments.
Wednesday, February 23, 2022, 8:00 am PST | 11:00 am EST

2021

▸ Holiday Hours December 20, 2021
picture of Holiday announcement
December 20, 2021

Holiday Hours

The PM Flow cytometry facility will be on weekend/holiday access from Saturday December 25 to Tuesday December 28th and from Saturday January 1st to Monday January 3rd, 2022, inclusive.

▸ Changes to sorting fees starting November 8th, 2021
picture of SBAR flow poster
November 1, 2021

Changes to sorting fees starting NOVEMBER 8th, 2021

1) Base rate of Sorts on Fusion will be charged at 85/h (corporate and after-hours fees will be affected proportionally). We will maintain the $75/h rate on all Astrios sorters.
2) Saturday sort requests will be charged at a premium 1.5X (after hours rate). If you have any questions or concerns about this update, please contact us at pmflow@uhnresearch.ca.

▸ REMEMBER TO LOG OUT OF WINDOWS ON OUR COMPUTERS!
picture of SBAR flow poster
June 22, 2021

REMEMBER TO LOG OUT OF WINDOWS ON OUR COMPUTERS!

In reviewing the user activity on the X-20 since we implemented the new Windows sign-in method, it has come to our attention that some of you are forgetting to log out at the end of your analyzer sessions...

▸ Decommissioning CantoII and XDP
picture of SBAR floJo poster
June 22, 2021

Decommissioning CantoII and XDP

PM Flow continues to update its instruments to better serve the research community. It is time to retire our older instruments. The CantoII and XDP will be decommissioned, and no longer available for use as of June 22 except for data retrieval. Please back up your data ASAP. If you have any questions, please, do not hesitate to contact us at pmflow@uhnresearch.ca.

▸ CytoFLEX webinar July 14th
picture of SBAR floJo poster
June 22, 2021

CytoFLEX webinar July 14th

Join us on July 14 th at 12:30 pm EST and learn how to Drive Your Flow Forward with the CytoFLEX flow cytometry platform.
We are excited to invite you to an hour of learning and engagement with your Beckman Coulter Life Sciences team, Natalia Fedianina...

▸ Introducing the SONY ID7000
picture of Sony ID7000
June 22, 2021

Introducing the SONY ID7000

Our new Sony ID7000 Spectral Analyzer has arrived and is being installed in Room 8-516!
User training will be available starting on August 16th, 2021. Please submit training requests to pmflow@uhnresearch.ca.

▸ Cytoflex S1 relocated to Room 10-609!
picture of SBAR floJo poster
June 10, 2021

Cytoflex S1 relocated to Room 10-609!

Please be advised that the CytoFLEX S1 instrument has been relocated to Room 10-609 on the 10th floor of our facility in order to make room downstairs for the new Sony analyzers. This means that both CytoFLEX instruments (i.e., the S1 and S2) are in the same room now.

▸ ATTENTION ALL PM FLOW USERS! May 05, 2021
picture of SBAR floJo poster
May 05, 2021

ATTENTION ALL PM FLOW USERS!

New! Starting from May 10, all users are required to record the 15 mins SIT and 1 min sample waste line cleaning procedures on the last tube of their experiment under BDFACS DIVA.

▸ Ask the Experts May 05, 2021
May 05, 2021

Ask the Experts

Join us on Thursday, May 13, 2021 8 a.m. PST for our Global Webinar - Ask the Experts: An Optimized Method for Accurate Spread Measurement and Its Use in Panel Design

▸ ATTENTION ALL FLOWJO USERS! April 22, 2021
picture of SBAR floJo poster
April 22, 2021

ATTENTION ALL FLOWJO USERS!

FlowJo licenses are renewed annually on June 1st.

▸ NEW Fusion cancellation policy
picture of SBAR allusers poster
March 23, 2021

NEW Fusion cancellation policy

As of April 1, 2021, the PMFlow facility will require 48 hours-notice to cancel sorts on the Fusion without penalty.

▸ Virtual Flow Cytometry Data Analysis Course Spring 2021
picture of moving equipment
January 25, 2021

Virtual Flow Cytometry Data Analysis Course Spring 2021

It's an online flow cytometry data analysis course being organized from March 8-11 by the Royal Microscopy Society in the UK. The cost of registration is 300 British pounds.

2020

▸ Instrument Relocation to Improve Safe Access
picture of moving equipment
June 5, 2020

Instrument Relocation to Improve Safe Access

We have recently relocated some of our analytical instruments in order to allow all instruments to be accessible at any time while maintaining appropriate physical distancing.

▸ ATTENTION ALL PMFlow USERS June 1, 2020
picture of SBAR allusers poster
June 1, 2020

ATTENTION ALL PMFlow USERS

Things you need to know about PMFlow Research Restart June 1, 2020

▸ ATTENTION ALL FLOWJO USERS! May 20, 2020
picture of SBAR floJo poster
May 20, 2020

ATTENTION ALL FLOWJO USERS!

FlowJo Analysis Software Migrates to Portal. Current Licenses expire May 31, 2020

2019

▸ Stratocore calendar
picture of calendar November
Oct 25, 2019

Stratocore calendar

The flow cytometry Calcium booking calender is no longer in use. The new Booking-Calendar application from Stratocore is live today!

▸ New Beckman Coulter Cytoflex Analyzers have arrived
picture of imaging workshop poster
Oct 25, 2019

New Beckman Coulter Cytoflex Analyzers have arrived

The first of our new Beckman Coulter Cytoflex Analyzers has arrived and will be available to our users in November. This instrument is equipped with 3 lasers (VBR) and will be capable of analyzing 13 fluorescent parameters simultaneously. Feel free to contact us for additional information and to inquire about training.

▸ FCS Express 7 Site License Demo
picture of fcs express bar
Sep 30, 2019

FCS Express 7 Site License Demo

Discover how to save time with your standard flow data analysis using UHN's FCS Express site license!

Analyzers

▸ Fortessa 1
Laser Name Wavelength Power Detector Channel Mirror Filter Parameter Test Parameter
Blue 488 50 A 1 685 LP 710/50 BP PerCP-Cy5_5 PerCP-Cy5_5
B 2 505 LP 530/30 BP FITC FITC
C 3 488/10 BP SSC
Violet 405 50 A 4 750 LP 780/60 BP BV786 BV786
B 5 690 LP 710/50 BP BV711 BV711
C 6 630 LP 660/20 BP BV650 BV650
D 7 595 LP 610/20 BP BV605 BV605
E 8 505 LP 525/50 BP AmCyan BV510
F 9 450/50 BP Pacific Blue BV421
Yel/Grn 561 50 A 10 750 LP 780/60 BP PE-Cy7 PE-Cy7
B 11 685 LP 710/50 BP PE-Cy5_5 PE-Cy5_5
C 12 600 LP 610/20 BP PE-Texas Red PE-Texas Red
D 13 586/15 BP PE PE
UV 355 20 A 14 690 LP 740/35 BP BUV737 BUV737
B 15 490 LP 515/30 BP BUV496 BUV496
C 16 379/28 BP BUV395 BUV395
Red 640 40 A 17 750 LP 780/60 BP APC-Cy7 APC-Cy7
B 18 690 LP 710/50 BP Alexa Fluor 700 APC-R700
C 19 670/14 BP APC APC
▸ Fortessa 2
Laser Name Wavelength Power Detector Channel Mirror Filter Parameter Test Parameter
Blue 488 50 A 1 685 LP 710/50 BP PerCP-Cy5_5 PerCP-Cy5_5
B 2 505 LP 530/30 BP FITC FITC
C 3 488/10 BP SSC
Violet 405 50 A 4 750 LP 780/60 BP BV786 BV786
B 5 690 LP 710/50 BP BV711 BV711
C 6 630 LP 660/20 BP BV650 BV650
D 7 595 LP 610/20 BP BV605 BV605
E 8 505 LP 525/50 BP AmCyan BV510
F 9 450/50 BP Pacific Blue BV421
Yel/Grn 561 50 A 10 750 LP 780/60 BP PE-Cy7 PE-Cy7
B 11 685 LP 710/50 BP PE-Cy5_5 PE-Cy5_5
C 12 600 LP 610/20 BP PE-Texas Red PE-Texas Red
D 13 586/15 BP PE PE
UV 355 20 A 14 690 LP 740/35 BP BUV737 BUV737
B 15 490 LP 515/30 BP BUV496 BUV496
C 16 379/28 BP BUV395 BUV395
Red 640 40 A 17 750 LP 780/60 BP APC-Cy7 APC-Cy7
B 18 690 LP 710/50 BP Alexa Fluor 700 APC-R700
C 19 670/14 BP APC APC
▸ X-20
Laser Name Wavelength Power Detector Channel Mirror Filter Parameter Test Parameter
Blue 488 100 A 3 655 LP 685/35 BP PerCP-Cy5-5 PerCP-Cy5_5
B 2 505 LP 525/50 BP FITC FITC
C 1 488/10 BP SSC
Grn 532 150 A 8 750 LP 780/60 BP PE-Cy7 PE-Cy7
B 7 685 LP 710/50 BP PE-Cy5.5 PE-Cy5.5
C 6 630 LP 660/20 BP PE-Cy5 PE-Cy5
D 5 600 LP 610/20 BP PE-Texas Red PE-Texas Red
E 4 575/25 BP PE PE
Red 640 40 A 11 750 LP 780/60 BP APC-Cy7 APC-Cy7
B 10 685 LP 710/50 BP APC-Alexa 700 APC-R700
C 9 670/30 BP APC APC
Violet 405 50 A 14 600 LP 610/20 BP BV605 BV605
B 13 505 LP 525/50 BP BV510 BV510
C 12 450/50 BP BV421 BV421
▸ Cytoflex S1
Laser Name Wavelength Power Channel Mirror Filter Parameter
Red 660 1 R763LP 763/43 AC7
2 R660LP 660/10 BP APC
3 R712LP 712/25 BP A700
Grn 561 4 Y610SP 610/20 PE-TR
5 Y763LP 763/43 PC7
6 Y585SP 585/42 PE
7 Y710LP 710/50 PE-Cy5.5
Blue 488 8 B690SP 690/50 BP PerCP-Cy5-5
9 B525SP 525/40 BP FITC
488/8 BP SSC
Violet 405 10 V450SP 450/45 BV421
11 V525SP 525/40 BV510
12 V610LP 610/20 BV605
13 V660LP 660/10 BV650
▸ Cytoflex S2
Laser Name Wavelength Power Channel Mirror Filter Parameter
Red 660 1 R763LP 763/43 AC7
2 R660LP 660/10 BP APC
3 R712LP 712/25 BP A700
Grn 561 4 Y610SP 610/20 PE-TR
5 Y763LP 763/43 PC7
6 Y585SP 585/42 PE
7 Y710LP 710/50 PE-Cy5.5
Blue 488 8 B690SP 690/50 BP PerCP-Cy5-5
9 B525SP 525/40 BP FITC
488/8 BP SSC
Violet 405 10 V450SP 450/45 BV421
11 V525SP 525/40 BV510
12 V610LP 610/20 BV605
13 V660LP 660/10 BV650

Sorters

▸ Fusion
Laser Name Wavelength Power Detector Channel Mirror Filter Parameter Test Parameter
Blue 488 50 A 1 685 LP 710/50 BP PerCP-Cy5_5 PerCP-Cy5_5
B 2 505 LP 530/30 BP FITC FITC
C 3 488/10 BP SSC
Violet 405 50 A 4 750 LP 780/60 BP BV786 BV786
B 5 690 LP 710/50 BP BV711 BV711
C 6 630 LP 660/20 BP BV650 BV650
D 7 595 LP 610/20 BP BV605 BV605
E 8 505 LP 525/50 BP AmCyan BV510
F 9 450/50 BP Pacific Blue BV421
Yel/Grn 561 50 A 10 750 LP 780/60 BP PE-Cy7 PE-Cy7
B 11 685 LP 710/50 BP PE-Cy5_5 PE-Cy5_5
C 12 600 LP 610/20 BP PE-Texas Red PE-Texas Red
D 13 586/15 BP PE PE
UV 355 20 A 14 690 LP 740/35 BP BUV737 BUV737
B 15 490 LP 515/30 BP BUV496 BUV496
C 16 379/28 BP BUV395 BUV395
Red 640 40 A 17 750 LP 780/60 BP APC-Cy7 APC-Cy7
B 18 690 LP 710/50 BP Alexa Fluor 700 APC-R700
C 19 670/14 BP APC APC
▸ Astrios 1
Laser Name Wavelength (nm) Power (mW) Detector Mirror Filter Fluors
Violet 405 55 A 418 DLP 405/10 V-SSC
B M 448/59 BV421
C 506 DLP 525/50 BV510
D 635 DLP 615/20 BV605
E 681 DLP 661/20 BV650
F 681 DLP 710/40 BV710
Blue 488 200 A M 488/6 B-SSC
B 495 DLP 525/50 FITC, AlexaFluor 488, GFP
C M 698/70 PerCP-Cy5.5, 7-AAD
Green 561 200 A M 579/16 TRITC, mRFP, PE, tdTomato
B 595 DLP 641/20 mCherry, PI, PE-Cy5, Texas Red
C 757DLP 692/75 7-AAD, PE-cy5.5
D M 795/70 PE-Cy7
Red 640 100 A M 642/10 R-SSC
B 650 DSP 671/30 APC, AlexaFluor 647
C 695 DSP 722/44 AF700
D 755 DSP 795/70 APC-Cy7, AlexaFluor 750
▸ Astrios 2
Laser Name Wavelength (nm) Power (mW) Detector Mirror Filter Fluors
Violet 405 55 A 418 DLP 405/10 V-SSC
B M 448/59 BV421
C 506 DLP 525/50 BV510
D 635 DLP 615/20 BV605
E 681 DLP 661/20 BV650
F 681 DLP 710/40 BV710
Blue 488 200 A M 488/6 B-SSC
B 495 DLP 525/50 FITC, AlexaFluor 488, GFP
C M 698/70 PerCP-Cy5.5, 7-AAD
Green 561 200 A M 579/16 TRITC, mRFP, PE, tdTomato
B 595 DLP 641/20 mCherry, PI, PE-Cy5, Texas Red
C 757DLP 692/75 7-AAD, PE-cy5.5
D M 795/70 PE-Cy7
Red 640 100 A M 642/10 R-SSC
B 650 DSP 671/30 APC, AlexaFluor 647
C 695 DSP 722/44 AF700
D 755 DSP 795/70 APC-Cy7, AlexaFluor 750